238F16AB7-CF7D-4876-9EE3-A7AD5F042363F1AC25E9-038A-4191-95C9-E27A2A602897F1AC25E9-038A-4191-95C9-E27A2A602897513287Emergency luminaire U21-std maintained, non maintained-350 lm-1h-LED6616073535.77 http://docdif.fr.grpleg.com/general/MEDIAGRP/NP-FT-GT//LE06909AE.pdfhttp://docdif.fr.grpleg.com/general/MEDIAGRP/CERTIF//LGFAJKRPTY.PDF Hospitality\Corridors\Emergency Lighting\Standard luminaires5F44BA20-2E7D-42B8-83B8-E2D91F16D683270233661607.jpg661607.jpg(PATHUPLOAD)\__upload\Legrand\Catalogue\imagesF1AC25E9-038A-4191-95C9-E27A2A6028970U21LED - indoor self-contained emergency lighting luminaires LED
  • LED maintained and non maintained units
  • Certified to IECand EN60598-2-22 standards
  • High power LEDs
  • IP 42 - IK 04
  • Duration: 1 and 3 hours. Ni-Cd or Ni-MH batteries
  • Recharge time: 24 hours. Charge monitor with a green LED
  • Power supply: 230 V~ ,%#%plusmn;10% - 50/60Hz. Class II
  • High capacity screw terminals (2 x 2.5 mm ²)
  • Flush-mounting in dry partitions (ceiling & wall): add flush-mounting frame Cat.No 6 617 20. Flush-mounting in masonry (brick or concrete wall): add both flush-mounting box Cat. No 0 617 21 and flush-mounting frame Cat.No 6 617 20
  • To be equipped with labels. Can be equipped withmetallic protection gridsCat.Nos 0 626 90/92

Standard luminaires
  • Require normal lighting manual switching off in order to test emergency lighting
Maintained / Non-maintained (M/NM)
  • Can also operate in Nonmaintainedmode according to the wiring of normal lighting
  • 350 lm - 1h (LEDs)
02123074.58

Emergency luminaire U21-std maintained, non maintained-350 lm-1h-LED

  1. Hospitality
  2.  > Corridors
  3.  > Emergency Lighting
  4.  > Standard luminaires
Availabilty:0
Code: 661607
U21LED - indoor self-contained emergency lighting luminaires LED
  • LED maintained and non maintained units
  • Certified to IECand EN60598-2-22 standards
  • High power LEDs
  • IP 42 - IK 04
  • Duration: 1 and 3 hours. Ni-Cd or Ni-MH batteries
  • Recharge time: 24 hours. Charge monitor with a green LED
  • Power supply: 230 V~ ,%#%plusmn;10% - 50/60Hz. Class II
  • High capacity screw terminals (2 x 2.5 mm ²)
  • Flush-mounting in dry partitions (ceiling & wall): add flush-mounting frame Cat.No 6 617 20. Flush-mounting in masonry (brick or concrete wall): add both flush-mounting box Cat. No 0 617 21 and flush-mounting frame Cat.No 6 617 20
  • To be equipped with labels. Can be equipped withmetallic protection gridsCat.Nos 0 626 90/92

Standard luminaires
  • Require normal lighting manual switching off in order to test emergency lighting
Maintained / Non-maintained (M/NM)
  • Can also operate in Nonmaintainedmode according to the wiring of normal lighting
  • 350 lm - 1h (LEDs)